Adults' past-day recall of sedentary time: reliability, validity, and responsiveness

Med Sci Sports Exerc. 2013 Jun;45(6):1198-207. doi: 10.1249/MSS.0b013e3182837f57.

Abstract

Purpose: Past-day recall rather than recall of past week or a usual/typical day may improve the validity of self-reported sedentary time measures. This study examined the test-retest reliability, criterion validity, and responsiveness of the seven-item questionnaire, Past-day Adults' Sedentary Time (PAST).

Methods: Participants (breast cancer survivors, n = 90, age = 33-75 yr, body mass index = 25-40 kg·m) in a 6-month randomized controlled trial of a lifestyle-based weight loss intervention completed the interviewer-administered PAST questionnaire about time spent sitting/lying on the previous day for work, transport, television viewing, nonwork computer use, reading, hobbies, and other purposes (summed for total sedentary time). The instrument was administered at baseline, 7 d later for test-retest reliability (n = 86), and at follow-up. ActivPAL3-assessed sit/lie time in bouts of ≥5 min during waking hours on the recall day was used as the validity criterion measure at both baseline (n = 72) and follow-up (n = 68). Analyses included intraclass correlation coefficients, Pearson's correlations (r), and Bland-Altman plots and responsiveness index.

Results: The PAST had fair to good test-retest reliability (intraclass correlation coefficient = 0.50, 95% confidence interval [CI] = 0.32-0.64). At baseline, the correlation between PAST and activPAL sit/lie time was r = 0.57 (95% CI = 0.39-0.71). The mean difference between PAST at baseline and retest was -25 min (5.2%), 95% limits of agreement = -5.9 to 5.0 h, and the activPAL sit/lie time was -9 min (1.8%), 95% limits of agreement = -4.9 to 4.6 h. The PAST showed small but significant responsiveness (-0.44, 95% CI = -0.92 to -0.04); responsiveness of activPAL sit/lie time was not significant.

Conclusion: The PAST questionnaire provided an easy-to-administer measure of sedentary time in this sample. Validity and reliability findings compare favorably with other sedentary time questionnaires. Past-day recall of sedentary time shows promise for use in future health behavior, epidemiological, and population surveillance studies.

Publication types

  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Accelerometry
  • Adolescent
  • Adult
  • Aged
  • Female
  • Follow-Up Studies
  • Humans
  • Mental Recall*
  • Middle Aged
  • Motor Activity
  • Outcome Assessment, Health Care
  • Reproducibility of Results
  • Sedentary Behavior*
  • Self Report*
  • Single-Blind Method
  • Surveys and Questionnaires
  • Time
  • Weight Reduction Programs*
  • Young Adult